Receive
updates to the mechanical interpretation information by e-mail |
| Date |
Subject |
Code Section |
| 08/15/2008 |
Appliance access |
ORSC sections M1305.1.3 and M1305.1.4 and OESC Article 110.26 |
| 06/15/2008 |
Motor and fan requirements for Hazardous Exhaust Systems |
2007 OMSC Section 510 |
| 05/21/2008 |
Bonding of Corrugated Stainless Steel Tubing |
OMSC C310 |
| 10/02/2006 |
LP Gas, Permits and inspections (Revised) |
Oregon One and Two Family Dwelling Specialty Code |
| 09/26/2005 |
Elevation of condensate pumps in a garage |
Section G2408.2 |
| 04/12/2005 |
Venting of Fuel-Gas Regulators |
Sections C410.3 and C403 (G2421 and G2414) |
| 04/01/2004 |
Testing of Hydronic Piping Systems |
Section 1209.2 |
| 10/01/2003 |
Installation of gas piping in a plenum |
Section C404.1 |
| 10/01/2002 |
Permanent Roof Top Access on Retrofit Installations
- Rescinded |
Section 306.5 |
| 10/01/2002 |
Guards for Retrofit Roof Top Units - Rescinded |
Section 304.9 |
| 10/01/2002 |
Mechanical Permit Requirements for Electric Cadet Heaters |
301.6 |
| 09/01/2002 |
Installation of Exhaust Fan in Other Similar Rooms Rescinded |
303.3 |
| 05/02/2000 |
Use of Wood Burning Appliances for Comfort Heating (Revised)
- Rescinded |
OSSC Section 310.11, Dwelling Code Sections 108 and 303.6 |
| 05/01/2000 |
Liquid Petroleum Gas, Permits and Inspections (Revised) |
OMSC Chapter 13 & Dwelling Code, Chapter 26 |
| 05/01/2000 |
Masonry Heater/Radiant Heat Systems (Revised)
- Rescinded |
Sections 107, 108, 109, 303.5, Chapter 10 and 1307.5 |
| 08/11/1999 |
Commercial Hoods and Kitchen Ventilation (Revised) |
Sections 202 and 507 |
| 07/15/1999 |
Gas Log Lighters (Revised, editorial)
- Rescinded |
Section 1004.1, 1308.1, 2606.4, 2205.4, and 2205.5 |
| 03/10/1994 |
Insulation Clearance to Listed Vents - Rescinded |
Section 5303(a)2C3 |
| 01/26/1994 |
Concealed Unions on Furnaces
- Rescinded |
OMSC Chapter 22 Dwelling Code Chapter 17 |
| 01/26/1994 |
Vibration Isolators - Rescinded |
93-91 OMSC Section 1002(f) & Dwelling Code Section M-1102.1.3 |
| 01/26/1994 |
2.5 Inch Thick Masonry Wall Protection - Rescinded |
Tables 5-A, 5-B(j) |
| 01/26/1994 |
Gas Piping Under Buildings - Rescinded |
OMSC Section 2213(b); Dwelling Code Section M-1707.1.5; NFPA 54, Section 1.2.9.5 |
| 11/19/1993 |
Unvented Gas-Burning Space Heaters |
OMSC Section 807(c); Dwelling Code Section M-1601 |
| 10/01/1993 |
Solid Fuel-Burning Appliance Exception to 1993 Oregon Energy Code Section 5306 - Rescinded |
Sections R-108.1, R-203.5 and 5306(a) |
| 12/03/1992 |
Duct Insulation Requirements for Retrofit of Existing Forced Air Heating Equipment |
Chapter 53, Section 5304(c) EXCEPTION and 5305(a) |
|
Copper Pipe Used for Gas Piping - Rescinded |
OMSC Chapter 22; Dwelling Code Chapter 17; NFGC Section 2.6.2 D |